ZHENG Guo, LONG Xinfeng. Retrofitting of burning bituminous coal for a 300MW unit boiler and the anti-coking countermeasures[J]. Thermal power generation, 2015, 44(11): 118-123.
ZHENG Guo, LONG Xinfeng. Retrofitting of burning bituminous coal for a 300MW unit boiler and the anti-coking countermeasures[J]. Thermal power generation, 2015, 44(11): 118-123.DOI:
In order to adapt to the changes in the coal market and satisfy the relative requirements
the1 025t/h boilers in 4×300 MW units of Zhanjiang Electric Power Company were retrofitted
the fuel was changed into bituminous coal with high volatile matters and the capacity of both the boiler and the turbine was enlarged.After the retrofitting
coking problem easily occurred in the boiler.Thus
the furnace coking risk was assessed by numerical simulation
and the boiler integral transformation scheme was proposed
which includes the pulverizing system retrofitting
changing the burners
increasing the heating surface area
applying horizontal bias burner
reducing the excircle diameter
and other anti-fouling measures.After this transformation
the boilers can safety burn bituminous coal with volatile content of above 40%(dry ash free basis)
and the fouling situation turned well
the boiler maximum continuous rating reached1 077t/h
the boiler efficiency was enhanced to 93.22%
and the steam temperature
steam pressure and steam flow rate all met the design requirements.However
due to low ash melting point
serious coking will occurred when burning Indonesia coal and Shenhun coal purely.It is recommended these two coals blending ratio be lower than 50%.