ZHANG Feiran, ZHOU Keyi, XU Qi, et al. Countermeasures for SCR denitration system of coal-fired unit during low-load operation[J]. Thermal power generation, 2016, 45(7): 78-83.
ZHANG Feiran, ZHOU Keyi, XU Qi, et al. Countermeasures for SCR denitration system of coal-fired unit during low-load operation[J]. Thermal power generation, 2016, 45(7): 78-83.DOI:
During low load operation of coal-fired power plants
the flue gas temperature at the economizer outlet is always too low to satisfy the requirements for temperature by the selective catalytic reduction(SCR)catalyst
thus the desulfurization efficiency is low.To solve this problem
this paper takes a supercritical 600 MW coal-fired unit as the research object to carry out transformations on feedwater bypass of the economizer
flue gas bypass of the economizer and staged arrangement of the economizer.The boiler thermal calculation results show that
under 50% THA condition
by the method of economizer classification
when the heating surface of Economizer 1reached 83% of the total heating surface area
and the that of Economizer 2is 17%
the temperature at the SCR reactor inlet reached 320 ℃
which satisfied the catalyst operation requirement.Moreover
the boiler thermal efficiency kept at 94.69%
indicating the transformation effect is the optimum.