Due to the strong reducing atmosphere and H_2S formation around the water wall of a supercritical opposed firing boiler
serious high temperature corrosion occurred in the water walls.To solve this problem
the single factor alternate method was applied to experimentally investigate the effects of main operating parameters on H_2S concentrations around side water wall.The results show that
on the basis of customary boiler operating condition
after a series of regulations
such as weakening the tertiary air swirl of the main burner appropriately
distributing the tertiary air flow as bowl type
strengthening the secondary air swirl of the main burner appropriately
increasing the swirling air ratio of the OFA burner
reducing direct air ratio of the OFA burner
increasing the running oxygen concentration appropriately
distributing the mills output uniformly
increasing the primary air velocity appropriately
and reducing the coal fineness
the H_2S concentration around the side water wall decreased from 876.5mg/m~3 to 352.2mg/m~3.The atmosphere around the water wall surface was greatly improved
and the security of the boiler operation was enhanced.