HUANG Jinyang, YANG Zheng, LU Jintao, et al. Failure analysis of flange used for urea hydrolysis equipment[J]. Thermal power generation, 2016, 45(6): 111-115.
HUANG Jinyang, YANG Zheng, LU Jintao, et al. Failure analysis of flange used for urea hydrolysis equipment[J]. Thermal power generation, 2016, 45(6): 111-115.DOI:
scanning electron microscope(SEM)and X-ray diffraction(XRD)
the failure behavior of a seal flange made by TP304 stainless steel used at outlet of the urea hydrolysis equipment for flue gas denitrification was analyzed.The results show that
the failure of the flange plate was mainly caused by the continuous pitting corrosion and dissolved corrosion in high temperature and pressure urea corrosive medium.The interface between the corrosive medium and flange plate was serrated and the corrosion products were mainly Fe and Cr oxides.Loose structure and a large number of holes and cracks appeared in the corrosion products.The TP304 austenitic stainless steel is unsuitable for the seal flange material for urea hydrolysis equipment in flue gas denitrificaiton.