AI Chenhui. Experimental research on co-firing high suffer content coals in bituminite-fired boiler[J]. Thermal power generation, 2017, 46(6): 56-61.DOI:
On a one-dimensional flame furnace and ignition furnace
blend burning tests for Shenhun coal and high sulfur content coal from Chongqing energy(Nengtou coal) were carried out. The influence of mixing proportion
coal fineness and operation oxygen content on ignition temperature
burn-out rate
slagging and pollutant mission of the blended coals were studied. The results show that
with an increase in mixing proportion of the Nengtou coal
the ignition temperature of the mixed fuel increased
the burn-out rate and slagging tendency decreased
and the emission concentration of NO_x and SO_2 rose substantially. The field blended coal combustion experiment in the power plant boiler indicated that
the boiler efficiency and slagging characteristics had no obvious change
while the NO_x emission concentration increased a little