WEI Xing, JIANG Xinghua, JIN Senwang, et al. Matching method for ultra low emission for a 300 MW circulating fluidized bed boiler with two stage desulfurization[J]. Thermal power generation, 2017, 46(6): 107-112.
WEI Xing, JIANG Xinghua, JIN Senwang, et al. Matching method for ultra low emission for a 300 MW circulating fluidized bed boiler with two stage desulfurization[J]. Thermal power generation, 2017, 46(6): 107-112.DOI:
In order to further increase the economy of SO_2 ultra low emission
an experimental study on matching strategy of dry desulfurization and semi-dry flue gas desulfurization for a 300 MW unit circulating fluidized bed(CFB) boiler was carried out. The results show that
the dry desulfurization gradually deviated from the high efficiency desulfurization range as the boiler load increased
and with the same desulfurization efficiency
the calcium sulfur ratio increased and the limestone utilization rate decreased. As the boiler load increased
it reached the high desulfurization range of semi dry flue gas desulfurization gradually
and with the same desulfurization efficiency
the calcium sulfur ratio decreased and the lime hydrate utilization rate increased. The desulfurization efficiency of the two-stage desulfurization system can reach above 99% and that of the semi-dry desulfurization method can reach up to 95%. The multi-parameter strategy has better economy than the single SO_2 factor matching strategy. The combined desulfurization in the furnace and outside the furnace can further lower the SO_2 emission
and has good SO_2 emission stability and regulating flexibility.