SHEN Boxiong, ZHANG Haohao, WU Hanming, et al. Deactivation prediction model for flue gas denitration catalyst V-W-TiO2[J]. Thermal power generation, 2017, 46(9): 24-30.
SHEN Boxiong, ZHANG Haohao, WU Hanming, et al. Deactivation prediction model for flue gas denitration catalyst V-W-TiO2[J]. Thermal power generation, 2017, 46(9): 24-30.DOI:
Aiming at solving the deactivation problem of catalyst for SCR system in coal-fired power plant
based on three main factors affecting the catalyst deactivation: chemical poisoning
pore plugging and fly ash abrasion
the corresponding deactivation function was formulated.Then the prediction model for catalyst activity was established.The actual operation data of a power plant's SCR system were used in model fitting
and the key parameters of deactivation involved in the model were obtained.The results show that
the order of the toxic oxides' deposition rate is K_2OCaONa_2OAs_2O_3
and the blocking rate is related to the concentration and size distribution of the fly ash.The abrasion coefficient has a relationship with the flue gas flow and velocity as well as the fly ash particles' properties.This prediction model can well predict the catalyst deactivation in actual power plant.