华北电力大学电站设备状态监测与控制教育部重点实验室
纸质出版日期:2017
移动端阅览
卫慧敏, 杜小泽, 杨立军, 等. 大型间接空冷塔塔形优化[J]. 热力发电, 2017,46(11):50-56.
WEI Huimin, DU Xiaoze, YANG Lijun, et al. Configuration optimization for a large-scale dry-cooling tower[J]. Thermal power generation, 2017, 46(11): 50-56.
间接空冷系统冷却塔的投资是大型空冷电站建设的主要组成部分。在满足机组冷端散热负荷要求的前提下
优化冷却塔塔形可以有效降低电站的造价
提高经济性。以典型600 MW间接空冷机组的空冷塔为研究对象
考虑空冷换热器前后空气密度差产生的抽吸作用
及其与空冷塔各个流动环节阻力作用的平衡
建立了空冷塔受结构尺寸影响的阻力与迎面风速的关联式
以此为基础
构建间接空冷塔的动力方程和传热方程;综合考虑空冷塔散热负荷、塔体结构和空冷散热器面积
以空冷系统总投资最小为目标
采用拉格朗日乘子法
建立间接空冷系统的优化数学模型。结果表明:黏性耗散和进口风速的转向造成的阻力与空冷塔尺寸参数密切相关;最小投资成本对应的空冷系统选型结果是减小空冷塔的尺寸
增加换热器管束的换热面积。该研究结果可为空冷机组空冷塔选型提供参考。
The investment cost of natural draft dry cooling tower is a major component of the total investment of a large-scale air-cooled power plant. On the premise of satisfying the requirement of heat dissipation load of the unit cold end
configuration optimization for the dry-cooling tower can decrease the total investment cost of an indirect dry cooling system effectively. Taking a typical dry-cooling tower of 600 MW in-direct air-cooled unit as the research object
considering the size effects
the correlation between tower losses and the windward velocity was presented
the suction effect caused by the air density difference at inlet and outlet of the air-cooled heat exchanger and the balance of pressure difference between the outside and the inside of the cooling tower were also considered. On this basis
the dynamic equations and heat transfer equations for the indirect air-cooling tower were established. An optimized mathematical model for the indirect air-cooled system was established by using the Lagrange multipliers with the minimum investment of air-cooled tower as an optimization objective function
comprehensively considering the heat dissipation load
tower structure and air cooling heat dissipation area. The result shows that
the losses due to viscosity and separation are closely related to the tower configuration
the type selection scheme for the air-cooled tower corresponding to the minimum investment cost is reducing the size of the tower and increasing the heating surface area of the heat exchanger. The analysis can provide references for the indirect air-cooled tower design.