MAO Yijun, HE Lijun, ZHANG Yifan, et al. Thermal hydrodynamic performance of vertically-upward water wall in an ultra-supercritical double-reheat boiler with high working parameters[J]. Thermal power generation, 2017, 46(12): 105-110.
MAO Yijun, HE Lijun, ZHANG Yifan, et al. Thermal hydrodynamic performance of vertically-upward water wall in an ultra-supercritical double-reheat boiler with high working parameters[J]. Thermal power generation, 2017, 46(12): 105-110.DOI:
the ultra-supercritical double reheat boiler has different characteristics
like more complex heat load distribution in the furnace
higher working fluid temperature
lower heat absorbing capacity of water in the large specific heat region
and so on.It means the design of thermal hydrodynamic is more difficult in the vertically-upward water wall of ultra-supercritical double reheat boiler.Taking the ultra-supercritical 660 MW double reheat boiler in Anyuan Power Plant as an example
the thermal hydrodynamic performance of the vertically-upward water wall of ultra-supercritical double reheat boiler was analyzed in detail
according to the numerical simulation and hydrodynamic calculation.The distributions of mass flow rate
working fluid temperature and water wall temperature were obtained.The results show that
under BMCR working condition
there are obvious flow differences and water wall temperature differences in both the upper furnace and lower furnace.The fluid in water wall of both the upper furnace and lower furnace appears a minus mass flow characteristic.Therefore
the mass flow rate in the middle region is higher
while the distributions of working fluid temperature and water wall temperature are in the opposite.The results can provide guidance for hydrodynamic design and improvement of vertically-upward water wall in ultra-supercritical double reheat boilers.