GU Weiwei, ZHANG Yonghai, LI Yuan, et al. Reason analysis for fracture occurred in axial induced draft fan blade of a 600 MW unit[J]. Thermal power generation, 2017, 46(12): 129-132.
GU Weiwei, ZHANG Yonghai, LI Yuan, et al. Reason analysis for fracture occurred in axial induced draft fan blade of a 600 MW unit[J]. Thermal power generation, 2017, 46(12): 129-132.DOI:
The blade of axial induced draft fan in a 600 MW unit fractured.To find out the reasons
particular investigations on blade fracture failure site
operation files and history data of the axial induced draft fan were performed.The physical and chemical tests and fracture analysis for the blade were implemented.The centrifugal stress and the vibration characteristics of the blade were analyzed using the finite element method.The results show that
the physical and chemical performance of the blade material satisfied the requirement
the static strength and vibration characteristics of the blade met the design standard
the major reason for the blade fracture was poor quality or improper process of the coating
which made micro cracks exist on the blade surface before or during the unit operation