LI Xinfeng, WEI Guanghui, WANG Liandong, et al. Coupling Law of Electromagnetic Irradiation to Metal Enclosure with Short Penetrative Wire[J]. 2016, 42(3): 987-993.
LI Xinfeng, WEI Guanghui, WANG Liandong, et al. Coupling Law of Electromagnetic Irradiation to Metal Enclosure with Short Penetrative Wire[J]. 2016, 42(3): 987-993.DOI:
揭示了短贯通导体引入电磁干扰的耦合机理。结果表明:当屏蔽效能为40 d B的开孔腔体加载短贯通导体后
腔体内部屏蔽效能明显下降
屏蔽效能最小值达到-15.29 d B;腔体外部裸露贯通导体长度增大3 cm
腔体的屏蔽效能降低约4 d B;腔体内部贯通导体长度主要影响腔体的谐振频点;贯通导体长度不变而内外部分长度变化时
腔体屏蔽效能和谐振频点均发生变化;贯通孔尺寸增大
导致腔体内部屏蔽效能下降;测试点距离贯通导体越远
屏蔽效果越好;贯通导体半径能够影响屏蔽效能和腔体谐振频点;腔体壁厚度每增加0.3 cm
谐振频率增大约8 MHz;平行于贯通导体的电场分量越大
腔体屏蔽效能越差。
Abstract
In order to study the coupling law of electromagnetic irradiation to enclosure with short penetrative wire
we established a coupling model of one enclosure with a short penetrative wire in CST. We also established a corresponding experiment platform based on the Gigahertz transverse electromagnetic(GTEM) chamber to verify the calculated results through experiments. Moreover
we analyzed influences of penetrative wire’s length and radius
size of aperture
the polarization direction of electric field on the electromagnetic coupling in enclosure with short penetrative wire under the condition of planar wave radiation
and revealed the coupling mechanism of penetrative wire induced electromagnetic interference. The results indicate that shielding effectiveness(SE) of an enclosure with aperture decreases from 40 d B to-15.29 d B when a wire is put in aperture. The SE of enclosure decreases by 4 d B when the length of external penetrative wire increases by 3 cm
while the resonance frequency is mainly influenced by the length of the penetrative wire inside the enclosure. When the length of a wire maintains a certain value but its length inside and outside the enclosure changes
both SE and resonance frequency change. The SE of enclosure descends when the aperture gets bigger. The SE of enclosure increases with increasing the distance from test point to penetrative wire. The radius of penetrative wire affects both SE and resonance frequency. The resonance frequency of enclosure increases by 8 MHz when the thickness of enclosure wall increases by every 0.3 cm. The higher the parallel electric field value is