To realize the efficient analysis of the long cable bundle terminated with non-linear loads
combining equivalent cable bundle method(ECBM) with simulation program with integrated circuit emphasis(SPICE) model method
we put forward a more reduced SPICE model. The equivalent steps of equivalent cable bundle method was adjusted
ECBM was developed
and the reduced method of nonlinear loads was presented. The results show that computational accuracy is reliable for electromagnetic pulse(EMP) coupling to a 2 m length cable bundle with four cores. and they are in good agreement. The reduced times are 0.64 s
0.98 s
and 1.23 s for linear loads
non-linear loads T15KE39 CA
and non-linear loads B32K130
respectively. Computational efficiency is greatly improved by above 60%. The results provide a guidance for the EMP analysis of the long cable bundle loaded by non-linear loads.