西安交通大学电力设备电气绝缘国家重点实验室
网络出版:2018-12-31,
纸质出版:2018
移动端阅览
王晨光, 姚学玲, 林海, 等. 过电压保护间隙主动场击穿触发回路的研究[J]. 高电压技术, 2018,44(12):3995-4002.
WANG Chenguang, YAO Xueling, LIN Hai, et al. Study of Active Field-breakdown Trigger Circuit for Surge Protection Gap[J]. 2018, 44(12): 3995-4002.
为提高过电压保护间隙SPG的保护水平以及与后级过电压保护器件之间的能量配合
设计了基于场致触发的主动型过电压保护间隙
建立了过电压保护间隙的主动触发回路的电路模型
得到了回路元件参数的数学表达式
优选了触发回路的元件参数并进行了过电压保护间隙性能的实验验证。实验结果表明主动场击穿触发回路有效提高了过电压保护间隙的保护水平:当放电间隙间距d在0.55~2.1mm的范围内
主动型过电压保护间隙的冲击击穿电压U
pulse
与直流击穿电压UDC的压比K减小至被动型过电压保护间隙压比的50%左右;在放电间隙间距d=0.95 mm的条件下
随着冲击电压峰值U
m
从3.6 kV升高至6.5 kV
U
pulse
由3.36 kV上升至4.55 kV
明显低于被动型保护间隙6.41kV的冲击击穿电压值。研究结果为主动型过电压保护间隙性能的提升、不同特性的过电压防护间隙的精确配合、过电压防护的机理及其应用技术的研究提供了理论与实验基础。
In order to improve the voltage protection level of the surge protection gap(SPG) and the coordination between the SPG and the surge protection devices(SPDs) in the secondary stage
we designed an SPG with an active field-breakdown trigger circuit
which was called the active SPG. The circuit model of the active trigger circuit was established and the mathematical expressions of the elements parameters in the circuit were obtained. In addition
the element parameters of the trigger circuit were selected to verify the performance of the active SPG. The results showed that the active field-breakdown trigger circuit effectively improved the voltage protection level of SPG. When the discharge gap distance d was in the range of 0.55 mm to 2.1 mm
the
voltage ratio K of the active SPG
which was defined as the specific value of the pulse breakdown voltage U
pulse
and the DC breakdown voltage UDC
was 50% less than the SPG without an active trigger circuit. In the condition that the discharge gap distance d was 0.95 mm
the peak value of the impulse voltage U
m
increased from 3.4 kV to 6.5 kV
and the U
pulse
was increased from 3.36 kV to 4.55 kV. It was obviously lower than 6.41 kV
which was the U
pulse
of the SPG without an active trigger circuit. The results of the study can provide a theoretical and experimental basis for the performance improvement of the active SPG and the accurate coordination of the SPDs with different characteristics. Besides
they had also laid the foundation for the research of the mechanism and application of overvoltage protection.