ZHANG Ruobing, LUO Gang, HUANG Haochen, et al. Influence of Electrode Structure on the Dimension Parameters of Gliding Arc Discharge Plasma[J]. 2019, 45(10): 3357-3364.
ZHANG Ruobing, LUO Gang, HUANG Haochen, et al. Influence of Electrode Structure on the Dimension Parameters of Gliding Arc Discharge Plasma[J]. 2019, 45(10): 3357-3364.DOI:
等离子体已无法超出电极末端。等离子体宽度是在电极长度为20 mm时达到最大。保持电极长度为20 mm
改变电极张角
发现张角越大
电弧沿电极的滑动距离越小
电极引导电弧滑动的作用无法得到充分发挥
导致滑动弧放电等离子体的尺寸减小。
Abstract
In order to obtain the influence of electrode structure(electrode length and electrode angle) on the size of the discharge plasma of the gliding arc
a gliding arc discharge(GAD) device which is easy to replace electrodes is designed. An oscilloscope was adopted to measure the electrical signal of the gliding arc discharge plasma
and the images of gliding arc discharge with the electrodes of different structures are taken by a high-speed cemera and DV cemera. The results show that
with the increase of flow rate
gliding arc discharge has three different states. The voltage waveform of the steady GAD plasma is a waveform whose peak value is gradually increasing
which is distinct from the voltage waveform of the traditional AC arc. When the power and the flow rate are constant
the length of plasma will decrease with the increase of the length of the electrodes. And the plasma cannot exceed the end of electrodes when the length of the electrodes reaches 50 mm. The width of plasma width reaches the maximum when the electrode length is 20 mm. When the length of the electrode is 20 mm
the gliding distance of the arc along the electrodes will decrease with the increase of opening angel of electrodes
which results in the reduction of the size of the GAD plasma.