清华大学工程物理系
网络出版:2020-02-29,
纸质出版:2020
移动端阅览
陈坚, 李静, 李和平, 等. 衰亡等离子体中产生离子输运初始电子温度效应的临界电子数密度判据[J]. 高电压技术, 2020,46(2):729-736.
CHEN Jian, LI Jing, LI Heping, et al. Critical Value of the Electron Number Density for the Initial Electron Temperature Effect of the Ion Transport in a Decaying Plasma[J]. 2020, 46(2): 729-736.
在无外加激励源存在的条件下
不同的等离子体初始参数对衰亡等离子体特性
特别是其内部粒子输运特性的影响会表现出与准稳态等离子体条件下不同的物理规律。为此以激光共振电离所产生的等离子体为研究对象
采用理论分析与粒子模拟相结合的手段
研究了在平行板直流电场作用下衰亡等离子体中带电粒子的输运特性
着重分析了初始电子温度对离子输运特性的影响规律
建立了产生离子输运初始电子温度效应的临界电子数密度判据。研究结果表明:衰亡等离子体在外加直流电场作用下的粒子输运特性会受到初始电子温度和电子数密度、外加电压幅值以及极板间距等多个因素的影响。在外加直流电压与极板间距保持不变的情况下
存在1个临界的电子数密度。当等离子体初始电子数密度低于这一临界数密度值时
初始电子温度将无法影响等离子体衰亡过程中的离子通量;而当初始电子数密度高于这一临界值时
离子衰亡时间将随着初始电子温度的升高而显著缩短。该研究结果在一定程度上揭示了等离子体衰亡过程中初始电子温度和电子数密度对带电粒子输运特性的耦合作用机制
也为实际应用中以提高离子引出效率为目标的关键等离子体初始参数和引出区域结构与工作参数等的调控提供了理论上的指导。
On condition that there exist no external excitation sources
influences of various initial plasma parameters on the characteristics of decaying plasmas
especially the particle transport features
are quite different from those occurring in quasi-steady plasmas. Consequently
we investigated the particle transport characteristics of a decaying plasma induced by the laser resonance photoionization method and confined between two electrostatically biased parallel plates. Based on the analytical and particle simulation methods
the influences of the initial electron temperature on the ion transport characteristics were investigated. A new criterion of the electron number density for determining the electron temperature effect on the ion transport process was established. The analytical and numerical results show that:(i) The ion transport features in the decaying plasmas under an externally electrostatic field can be influenced by various parameters
e.g.
the initial electron temperature and number density
the amplitude of the externally applied voltage
and the gap spacing between electrodes;(ii) With a constant external voltage and gap spacing
there exists a critical value of electron number density
and the initial electron temperature has no effects on the ion transport process when the initial electron number density is lower than the critical electron number density;(iii) Once the initial electron number density is higher than its critical value
the decaying time of ions will decrease significantly with the increase of the initial electron temperature. The results in the study reveal the coupling mechanisms of the initial electron temperature and number density on the transport properties of the charged particles in the decaying plasmas. The results also provide a guidance for the adjustment of the initial key plasma parameters
geometrical and operating parameters of the ion extractors aiming at improving the ion extraction efficiency.