葛铭, 姜志成, 吕智嘉, 王佳杨, 仇召宏, 张守玉. 粉量分布不均对1000 MW机组对冲锅炉的影响及调整[J]. 中国电力, 2024, 57(1): 219-229. DOI: 10.11930/j.issn.1004-9649.202304081
引用本文: 葛铭, 姜志成, 吕智嘉, 王佳杨, 仇召宏, 张守玉. 粉量分布不均对1000 MW机组对冲锅炉的影响及调整[J]. 中国电力, 2024, 57(1): 219-229. DOI: 10.11930/j.issn.1004-9649.202304081
GE Ming, JIANG Zhicheng, LV Zhijia, WANG Jiayang, QIU Zhaohong, ZHANG Shouyu. The Influence of Unevenly Distributed Powder on a 1000 MW Opposed Firing Boiler and the Counter Measures[J]. Electric Power, 2024, 57(1): 219-229. DOI: 10.11930/j.issn.1004-9649.202304081
Citation: GE Ming, JIANG Zhicheng, LV Zhijia, WANG Jiayang, QIU Zhaohong, ZHANG Shouyu. The Influence of Unevenly Distributed Powder on a 1000 MW Opposed Firing Boiler and the Counter Measures[J]. Electric Power, 2024, 57(1): 219-229. DOI: 10.11930/j.issn.1004-9649.202304081

粉量分布不均对1000 MW机组对冲锅炉的影响及调整

The Influence of Unevenly Distributed Powder on a 1000 MW Opposed Firing Boiler and the Counter Measures

  • 摘要: 针对1000 MW机组对冲锅炉存在的偏烧问题进行了试验研究,结果发现粉量不均是偏烧的主要原因。粉量分布、煤粉细度分布均呈现典型的间隔分布趋势,且两者分布呈正相关。粉量分布不均、煤粉细度的偏差以及二次风箱风量分配特性等因素共同造成了炉内偏烧。为缓解炉内偏烧,从煤粉细度、燃烧器配风、燃尽风摆角和贴壁风开度等方面进行了调整。试验发现,燃尽风开度和摆角调整对于炉内偏烧的影响最为明显。燃尽风开度减小、燃尽风摆角由中间向两侧摆动有助于缓解偏烧。通过调整,屏过出口汽温偏差由40 ℃降低到10 ℃以内,省煤器出口氧量最低点由调整前的低于1%提高到调整后不低于2%;CO浓度最高点由调整前的5000 μL/L以上降低到调整后的500 μL/L以下,使该机组偏烧问题得到大幅度缓解。

     

    Abstract: An experimental study was carried out on deviant combustion of a 1000 MW opposed firing boiler. It was found that the powder deviation is the main factor. The distributions of powder amount and pulverized coal fineness demonstrated a typical interval distribution trend as well as a positive correlation. The factors such as uneven distribution of powder amount, deviation of pulverized coal fineness and air distribution characteristics of secondary-air-box led to the deviant combustion in the furnace. In order to alleviate the deviant combustion in the furnace, the fineness of pulverized coal, the air distribution of the burner, the swing angle of the burning wind, and the opening of closing-to-wall air were adjusted. It was found that the adjustment of burning wind opening and swing angle have the most significant influence. The decrease of burning wind opening and the swing angle of burning wind from the middle to both sides were helpful to alleviate the deviant combustion. After adjustment, the deviation of steam temperature at screen superheater outlet was reduced from 40 ℃ to less than 10 ℃. Under the full load condition, the lowest point of oxygen concentration at the outlet of the economizer was increased from less than 1% to more than 2%. The highest point of CO concentration decreased from more than 5000 μL/L to less than 500 μL/L. The deviant combustion was greatly alleviated. The combustion adjustment could provide reference for the same type of units to solve the problem of deviant combustion.

     

/

返回文章
返回