一种低温余热驱动的新型功冷联供系统

A Novel Power/Cooling Cogeneration System Driven by Low-grade Waste Heat

  • 摘要: 为了充分利用低温余热,提出了一种以氨水为工质的新型功冷联供复合循环系统,该系统以Goswami循环为基础,耦合了氨吸收/喷射式制冷方式。该新型功冷联供系统可显著提高Goswami循环的制冷能力,在改变分流比时,还能实现系统输出冷功比连续可调。通过热力学建模对系统进行模拟计算,结果表明,在给定工况下该新型功冷联供系统的联供热效率为12.16%,联供?效率为19.05%,系统?损失主要集中在换热器、精馏器、锅炉这3个部件。分析了吸收器温度、循环压力、锅炉出口氨蒸气温度、分流比这些关键参数对联供系统输出功、制冷量、联供热效率以及联供?效率的影响。

     

    Abstract: In order to recovery low temperature waste heat in a more useful way, a novel ammonia-water power and cooling cogeneration system was proposed and investigated. The system which was based on Goswami power/cooling cogeneration system can improve the refrigerating capacity by coupling the ammonia absorption-ejector refrigeration, and it can also continuously adjust the cooling-to-power ratio only by changing the split ratio. A mathematical model was developed to simulate the system performance and the results show that the combined thermal efficiency is 12.16% and the combined exergy efficiency is 19.05%, under the given condition, respectively. The exergy destruction mainly occurs in the recovery heat exchanger, rectifier and boiler. Parametric study shows that the absorber temperature, cycle highest pressure, ammonia vapor temperature at boiler outlet, cycle lowest pressure and separate ratio have significant effects on the net work output, total refrigeration output, combined thermal efficiency and combined exergy efficiency.

     

/