曾志杰, 肖华锋, 高博, 丁津津, 王政, 花为, 程明. 并网逆变器小信号建模简化方法与应用[J]. 中国电机工程学报, 2020, 40(21): 7002-7012. DOI: 10.13334/j.0258-8013.pcsee.191617
引用本文: 曾志杰, 肖华锋, 高博, 丁津津, 王政, 花为, 程明. 并网逆变器小信号建模简化方法与应用[J]. 中国电机工程学报, 2020, 40(21): 7002-7012. DOI: 10.13334/j.0258-8013.pcsee.191617
CENG Zhi-jie, XIAO Hua-feng, GAO Bo, DING Jin-jin, WANG Zheng, HUA Wei, CHENG Ming. Simplified Small-signal Modeling Method of Grid-connected Inverters and Its Applications[J]. Proceedings of the CSEE, 2020, 40(21): 7002-7012. DOI: 10.13334/j.0258-8013.pcsee.191617
Citation: CENG Zhi-jie, XIAO Hua-feng, GAO Bo, DING Jin-jin, WANG Zheng, HUA Wei, CHENG Ming. Simplified Small-signal Modeling Method of Grid-connected Inverters and Its Applications[J]. Proceedings of the CSEE, 2020, 40(21): 7002-7012. DOI: 10.13334/j.0258-8013.pcsee.191617

并网逆变器小信号建模简化方法与应用

Simplified Small-signal Modeling Method of Grid-connected Inverters and Its Applications

  • 摘要: 随着分布式电源在配电网中占比的增加,并网逆变器与电网动态交互导致的谐波谐振问题日益凸显,逆变器的小信号建模是分析"逆变器–电网"耦合系统谐波稳定性的基础。该文基于逆变器各典型环节在dq坐标系下的小信号模型,提出改进的阻抗建模方法以减少矩阵运算和耦合项,强化逆变器阻抗模型与物理环节的联系,建立起具有明确物理意义的简化阻抗模型。该文在上述模型简化过程中引入有功导纳和无功导纳,有助于探明稳定工作点变化经锁相环对逆变器阻抗特性和系统稳定性的影响。最后,通过频域分析结果和时域仿真结果证明了提出的简化逆变器阻抗模型可用于"逆变器–电网"耦合系统谐振机理分析和稳定性预判。

     

    Abstract: With the increasing proportion of distributed generations in distribution networks, harmonic resonance problems caused by interactions between grid-tied inverters and weak grid are becoming increasingly prominent. Small-signal modeling of inverters is the foundation of harmonic stability analysis of the inverter-weak grid coupling system. Based on the small signal model of typical grid-connected inverters in dq coordinate, a simplified impedance modeling method has been proposed in this paper. In the modeling process, matrix operations were reduced and the coupling terms between d and q channels were categorized into negligible and non-negligible parts, so that the connections among inverter impedance terms and the physical segments of inverters can be highlighted to strengthen physical interpretations of dq impedance. In addition, the concepts of active power admittance and reactive power admittance were introduced to demonstrate the influence mechanism of stable operating point’s variations on system stability through phase locked loop(PLL). Finally, the theoretical analysis in frequency domain and simulation results in time domain were provided to prove that the proposed simplified impedance model can be used to analyze the resonance mechanism and predict the stability of the inverter-weak grid coupling system.

     

/

返回文章
返回