空气源相变蓄能复叠式热泵供暖系统的研究
RESEARCH ON AIR SOURCE PHASE CHANGE ENERGY STORAGE CASCADE HEAT PUMP HEATING SYSTEM
-
摘要: 以空气源相变蓄能复叠式热泵供暖系统为基础,选取晴天、阴雨雪天气2个典型天气工况分别对热泵、储能等各部分模块进行试验数据采集,通过理论计算与实验分析表明,系统在冬季晴天时系统COP要明显高于阴雨雪天气工况,系统在极端天气工况下,随着室外环境温度逐步增大,热泵耗功缓缓下降,而随着环境温度降低,热泵耗功呈上升趋势。研究结果表明,较高的蒸发温度及较低的冷凝温度使热泵循环COP值处于较高水平,因此在不同工况下时,系统仍可高效稳定运行。Abstract: Based on the air source phase change energy storage cascade heat pump heating system,two typical weather conditions of sunny,rainy and snow weather are selected to collect experimental data for each part of the heat pump and energy storage. The theoretical calculation and experimental analysis show that when the system is sunny in winter,the system COP is obviously higher than the rainy and snowy weather conditions. Under the extreme weather conditions,the heat pump consumes slowly as the outdoor ambient temperature gradually increases,and as the ambient temperature decreases. The heat pump power consumption is on the rise;the research results show that the higher evaporation temperature and lower condensation temperature make the heat pump cycle COP value at a higher level,so the system can still operate efficiently and stably under different working conditions.