摘要: 介绍了2021年第四季度清徐精细化工循环产业园区大工业用电负荷情况,分析、推算出电网发生主变“N-1”故障后,现运行方式下电网所承载的巨大风险,通过分析、测算、比较,提出了进一步优化太原电网运行方式的改进方案。Abstract: The power load of large industry in Qingxu Fine Chemical Recycling Industrial Park in the fourth quarter of 2021 is introduced,the huge risks carried by the power grid under the current operation mode after the occurrence of the main transformer "N-1" failure are analyzed and calculated.The improvement scheme to further optimize the operation mode of Taiyuan power grid is put forward based on analysis,calculation and comparison.