张皓, 马国庆, 姚金霞, 李鹏飞, 段玉兵. 基于有限元模拟的变电站电缆沟道火灾蔓延仿真研究[J]. 山东电力技术, 2022, 49(9): 8-13.
引用本文: 张皓, 马国庆, 姚金霞, 李鹏飞, 段玉兵. 基于有限元模拟的变电站电缆沟道火灾蔓延仿真研究[J]. 山东电力技术, 2022, 49(9): 8-13.
ZHANG Hao, MA Guo-qing, YAO Jin-xia, LI Peng-fei, DUAN Yu-bing. Fire Spread Simulation for Cable Trench of Substation Based on Finite Element Method[J]. Shandong Electric Power, 2022, 49(9): 8-13.
Citation: ZHANG Hao, MA Guo-qing, YAO Jin-xia, LI Peng-fei, DUAN Yu-bing. Fire Spread Simulation for Cable Trench of Substation Based on Finite Element Method[J]. Shandong Electric Power, 2022, 49(9): 8-13.

基于有限元模拟的变电站电缆沟道火灾蔓延仿真研究

Fire Spread Simulation for Cable Trench of Substation Based on Finite Element Method

  • 摘要: 变电站电缆沟用以敷设站内用电系统的低压动力电缆、控制电缆、通信电缆和光缆,是站内电能传输和信息传输的重要通道。沟道内电缆一旦起火蔓延,将导致变电站整站电能和信息中断,造成严重电网事故。火灾蔓延趋势研究是实现电缆火灾预警及自动灭火,提升线路火灾防护能力的基础。建立基于有限元模拟的变电站电缆沟火灾蔓延仿真模型,研究不同分层敷设方式对电缆沟火灾蔓延趋势的影响。研究发现电缆沟道火灾蔓延以纵向蔓延为主,适当减少敷设的电缆层数可有效延缓火势发展,降低电缆火灾损失;电缆分层敷设方式对火灾后电缆沟道温度场的影响不大;在电缆沟道火灾过程中,温度场及有毒气体浓度分布存在显著的分层现象。

     

    Abstract: The cable trench is used to lay the low-voltage power cable,control cable,communication cable and optical cable of the power system in substation,which is an important channel for power transmission and information transmission.Once the cable in the trench catches fire and spreads,the power and information of the whole substation will be interrupted,resulting in serious power grid accidents. The research on fire spread trend is the basis of realizing cable fire early warning,automatic fire extinguishing and improving the fire protection ability of the line. The simulation model of substation cable trench fire spread based on finite element method was established.The influence of different layered laying methods on the fire spread trend of cable trench was studied.It was found that the fire spread in cable trench is mainly longitudinal,and therefore reducing the number of cable layers can effectively delay the development of fire and reduce the loss of cable fire.The layered cable laying method has little effect on the temperature field of cable trench after fire.In the process of cable trench fire,there is a significant stratification phenomenon in the temperature field and toxic gas concentration distribution.

     

/