关怀, 王建, 王志浩, 白云峰, 艾方兴, 曲辰, 王海营, 李庆鹏. 350MW亚临界锅炉屏式过热器爆管分析及预防[J]. 发电设备, 2023, 37(4): 269-272. DOI: 10.19806/j.cnki.fdsb.2023.04.012
引用本文: 关怀, 王建, 王志浩, 白云峰, 艾方兴, 曲辰, 王海营, 李庆鹏. 350MW亚临界锅炉屏式过热器爆管分析及预防[J]. 发电设备, 2023, 37(4): 269-272. DOI: 10.19806/j.cnki.fdsb.2023.04.012
Guan Huai, Wang Jian, Wang Zhihao, Bai Yunfeng, Ai Fangxing, Qu Chen, Wang Haiying, Li Qingpeng. Analysis and Prevention of Tube Explosion of the Platen Superheater in a 350 MW Subcritical Boiler[J]. POWER eQUIPMENT, 2023, 37(4): 269-272. DOI: 10.19806/j.cnki.fdsb.2023.04.012
Citation: Guan Huai, Wang Jian, Wang Zhihao, Bai Yunfeng, Ai Fangxing, Qu Chen, Wang Haiying, Li Qingpeng. Analysis and Prevention of Tube Explosion of the Platen Superheater in a 350 MW Subcritical Boiler[J]. POWER eQUIPMENT, 2023, 37(4): 269-272. DOI: 10.19806/j.cnki.fdsb.2023.04.012

350MW亚临界锅炉屏式过热器爆管分析及预防

Analysis and Prevention of Tube Explosion of the Platen Superheater in a 350 MW Subcritical Boiler

  • 摘要: 针对某350 MW亚临界燃煤机组的二级屏式过热器爆管事故,通过爆口宏观形貌观察、硬度测量、过热器减温水逻辑分析等对爆管原因进行分析。结果表明该次受热面爆管是由于过热器水塞引发过热器管短时超温导致的,通过对过热器减温水逻辑进行优化,并且制定多层面预防措施,可以降低屏式过热器爆管的可能性,进而保证机组安全稳定运行。

     

    Abstract: To solve the problem of the tube explosion of the secondary platen superheater in a 350 MW sub-critical coal-fired power plant, analyses were conducted on the tube explosion reason with the macro-morphology observation of the burst, the hardness measurement, the logic analysis of the attemperating water for superheater, etc. Results show that the tube explosion is caused by the short-term overtemperature of the superheater tube, which is resulted from the water plug of the superheater. The tube explosion possibility of the platen superheater can be reduced through optimizing the logic the of the attemperating water for superheater and formulating multi-level preventive measures. This may ensure the safety and stability of the unit operation.

     

/