Advanced Search+
Analysis and Solution on Low Reheat Temperature of 660MW Ultra Supercritical Boiler[J]. 能源电力期刊集群平台, 2022, (0).
Citation: Analysis and Solution on Low Reheat Temperature of 660MW Ultra Supercritical Boiler[J]. 能源电力期刊集群平台, 2022, (0).

Analysis and Solution on Low Reheat Temperature of 660MW Ultra Supercritical Boiler

  • Abstract: This paper analyzes the main reasons for the low reheat temperature of 660MW ultra supercritical boiler in a power plant, and puts forward the solutions. By reducing the opening of secondary air and central air of each layer of burner, strengthening soot blowing on the boiler heating surface, increasing the intermediate point temperature, reducing the primary air pressure and reducing the burnout air volume, the reheat temperature is effectively increased and the exhaust gas temperature is reduced and the boiler efficiency is improved.
  • loading

Catalog

    Turn off MathJax
    Article Contents

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return