As building integrated photovoltaic/thermal(BIPV/T)walls are structurally different from ordinary walls
which leads to changes in their thermal and moisture insulation performance
this study takes Shenyang
a cold region
as a case study. A two-dimensional numerical model of coupled heat and moisture transfer was established to study the internal transfer processes inside the BIPV/T walls under the winter conditions
and to experimentally validate the validity of the method. Comparing the BIPV/T wall with a conventional externally insulated wall
the results show that the time lag factor (τ=4-5 h) and attenuation factor (=0.064) of the BIPV/T wall are superior to those of the ordinary wall (τ=2-4 h
=0.151)
indicating better thermal performance. It can significantly improve the thermal comfort of the indoor environment. The internal water content of BIPV/T wall is 6% lower than that of ordinary wall
and it can accelerate the decrease of water content in the wall
keeping the moisture content within BIPV/T walls low. The probability of producing freeze-thaw damage in BIPV/T walls is 61.56% lower than that of ordinary walls
which improves the durability of the building envelope. The air channels of the BIPV/T wall can play a role in cooling down the PV modules
whose photovoltaic conversion efficiency is consistently above 18%.
关键词
Keywords
references
CORTI P, CAPANNOLO L, BONOMO P, et al.Comparative analysis of BIPV solutions to define energy and cost-effectiveness in a case study[J]. Energies, 2020, 13(15): 3827.
GB/T 51368—2019, 建筑光伏系统应用技术标准[S]. GB/T 51368—2019, Application technical standard of building photovoltaic system[S].
ATHIENITIS A K, BARONE G, BUONOMANO A, et al.Assessing active and passive effects of façade building integrated photovoltaics/thermal systems: dynamic modelling and simulation[J]. Applied energy, 2018, 209: 355-382.
CHOW T T, FONG K F, CHAN A L S, et al. Potential application of a centralized solar water-heating system for a high-rise residential building in Hong Kong[J]. Applied energy, 2006, 83(1): 42-54.
JI J, YI H, PEI G, et al.Study of PV-Trombe wall assisted with DC fan[J]. Building and environment, 2007, 42(10): 3529-3539.
JI J, YI H, HE W, et al.Modeling of a novel Trombe wall with PV cells[J]. Building and environment, 2007, 42(3): 1544-1552.
AGATHOKLEOUS R A, KALOGIROU S A, KARELLAS S.Exergy analysis of a naturally ventilated building integrated photovoltaic/thermal (BIPV/T) system[J]. Renewable energy, 2018, 128: 541-552.
TEO H G, LEE P S, HAWLADER M N A. An active cooling system for photovoltaic modules[J]. Applied energy, 2012, 90(1): 309-315.
YU G, YU J, HU Y, et al.Moisture transport analysis for integrated structures of flat plate solar collector and building envelope[J]. Solar energy, 2021, 217: 145-154.
GHOLAMI H, RØSTVIK H N. Economic analysis of BIPV systems as a building envelope material for building skins in Europe[J]. Energy, 2020, 204: 117931.
VASILYEV G P, LICHMAN V A, PESKOV N V, et al.Simulation of heat and moisture transfer in a multiplex structure[J]. Energy and buildings, 2015, 86: 803-807.
RAHMAN M M, HASANUZZAMAN M, RAHIM N A.Effects of various parameters on PV-module power and efficiency[J]. Energy conversion and management, 2015, 103: 348-358.
XIE H, YU B, WANG J, et al.A novel disinfected Trombe wall for space heating and virus inactivation: concept and performance investigation[J]. Applied energy, 2021, 291: 116789.
朱自强. 应用计算流体力学[M]. 北京: 北京航空航天大学出版社, 1998.
BELLEUDY C, WOLOSZYN M, CHHAY M, et al.A 2D model for coupled heat, air, and moisture transfer through porous media in contact with air channels[J]. International journal of heat and mass transfer, 2016, 95: 453-465.
GB 50176—2016, 民用建筑热工设计规范[S].GB 50176—2016, Code for thermal design of civil buildings[S].
GB 50736—2012, 民用建筑供暖通风与空气调节设计规范[S].GB 50736—2012, Design code for heating ventilation and air conditioning of civil buildings[S].
ASAN H, SANCAKTAR Y S.Effects of wall's thermophysical properties on time lag and decrement factor[J]. Energy and buildings, 1998, 28(2): 159-166.
JIN X, ZHANG X S, CAO Y R, et al.Thermal performance evaluation of the wall using heat flux time lag and decrement factor[J]. Energy and buildings, 2012, 47: 369-374.
KONG F H, ZHANG Q L.Effect of heat and mass coupled transfer combined with freezing process on building exterior envelope[J]. Energy and buildings, 2013, 62: 486-495.
STRAUBE J, SCHUMACHER C, MENSINGA P.Assessing the freeze-thaw resistance of clay brick for interior insulation retrofit projects[C]// Proceedings of the XI International Conference Thermal Performance of the Exterior Envelopes of Whole Buildings. Clearwater, FL, USA, 2010.