WANG Jun. Single-phase inverter power supply control for chemical instrumentation based on a second-order generalized integrator[J]. Ningxia Electric Power, 2026, (3).
DOI:
WANG Jun. Single-phase inverter power supply control for chemical instrumentation based on a second-order generalized integrator[J]. Ningxia Electric Power, 2026, (3).DOI: 10.3969/j.issn.1672-3643.2026.03.010.
Single-phase inverter power supply control for chemical instrumentation based on a second-order generalized integrator
To provide stable supply voltage for chemical instrumentation while ensuring that power quality meets international standards
this paper proposes a single-phase inverter power supply control strategy based on a second-order generalized integrator (SOGI).First
the control architecture of a single-phase inverter power supply system for chemical instrumentation is established.Based on this architecture
a voltage control strategy employing the SOGI and a proportional-integral (PI) controller is designed.The stability of the control system under different load conditions is then analyzed to verify its robustness.Finally
simulation results under various load conditions and load step-change scenarios are presented
analyzing the output voltage
control system variables and output power quality.The results demonstrate that the proposed control strategy ensures voltage stability for chemical instrumentation and guarantees compliance with power quality standards.