王之龙, 于东立, 门向阳, et al. Optimal configuration of energy interconnection microgrid system with compressed air energy storage[J]. 2018, 20(6).
DOI:
王之龙, 于东立, 门向阳, et al. Optimal configuration of energy interconnection microgrid system with compressed air energy storage[J]. 2018, 20(6). DOI: 10.3969/j.issn.1009-1831.2018.06.010.
Optimal configuration of energy interconnection microgrid system with compressed air energy storage
An energy interconnect microgrid system model with distributed photovoltaic
CAES
demand side response
gas turbine and other equipment is proposed.Then the minimum annual operating cost
including installation cost
energy cost and demand side response cost
is set as the optimization goal.The impact of the number of distributed photovoltaic cells
the configuration of devices
CAES
demand side responses and V2G on device capacity allocation and various costs in the microgrid are analyzed under different scenarios.In particular
the effects of parameters such as the turbine pressure
temperature of the CAES and with or without V2G on the microgrid system are considered.The model proposed can rationalize the equipment capacity configuration and reduce the annual operating cost of energy interconnection microgrid.