SUN Qi, CHENG Wei, ZHANG Tianyu, et al. Research on Automatic Mapping Technology of Power Traceability Diagram Based on Directed Acyclic Graph[J]. 2025, 45(2): 104-109.
SUN Qi, CHENG Wei, ZHANG Tianyu, et al. Research on Automatic Mapping Technology of Power Traceability Diagram Based on Directed Acyclic Graph[J]. 2025, 45(2): 104-109. DOI: 10.3969/j.issn.1008-0198.2025.02.014.
Research on Automatic Mapping Technology of Power Traceability Diagram Based on Directed Acyclic Graph
Aiming at the demand for power traceability mapping
a power traceability automatic mapping technology based on directed acyclic graphs is proposed. The layout algorithm of power grid equipment which is the core method for automatic mapping of power traceability diagrams has been designed based on on power grid equipment and connection relationships data
which mainly includes node layering
node sorting and horizontal coordinate calculation steps. An important power load is taken as an example to carry out power traceability automatic mapping experiment and it is found that the nodes in the graph are evenly distributed
with few intersecting connecting lines. The mapping results are overall reasonable and aesthetically pleasing.
SUGIYAMA K,TAGAWA S,TODA M.Methods for visual understanding of hierarchical system structures[J]. IEEE Transactions on Systems,Man,and Cybernetics,1981,11(2):109-125.
JUNGER M,MUTZEL P.2-layer straightline crossing minimization:performance of exact and heuristic algorithms[J]. Journal of Graph Algorithms and Applications,1997,1(1):1-25.
BRANDES U,KÖPF B. Fast and simple horizontal coordinate assignment[C]//Proceedings of the 9th International Symposium on Graph Drawing,2001-09-23. Vienna,Austria. 2001.