Hu Da-wei, Li Guo-xin, Zhao Gao-wen. AntiCorrosion Performance of Hotdip Galvanized Coating During Neutral Salt Spray Test[J]. 2016, 33(4): 74-78.DOI: 10.3969/j.issn.1007-7162.2016.04.013.
AntiCorrosion Performance of Hotdip Galvanized Coating During Neutral Salt Spray Test
Two hot-dip galvanized products are applied onto the steel substrates
then the specimens are tested for 5000h by the neutral salt spray and there are obvious differences in the anti-corrosion performance between the coatings. The thickness loss of coatings
crystal material compositions and microstructures of the coatings are analyzed by Zinc coating thickness loss test method
differential scanning calorimetry (DSC)
and X-ray diffraction analysis (XRD). The results show that there is no significant difference of the corrosion products and corrosion mechanisms between two coatings. Nevertheless
the hot-dip galvanized production process
the degree of densification of the corrosion products in coating are the primary factors influencing the anticorrosion performance of the hot-dip galvanized coating.