Burst Analysis on Platen Superheater Tube of 600MW Supercritical Units
摘要
通过对爆管样品的宏观形貌分析、化学成分分析、硬度检验、金相组织检验和扫描电镜分析
对某超临界机组T91材质的屏式过热器爆管原因进行分析。结果表明
爆管试样硬度偏低
这与显微组织的变化相关。T91钢的正常供货组织应为回火马氏体
而爆管样品爆口处的金相组织显示马氏体板条位向消失
演变为铁素体和于晶界处析出的颗粒较大的碳化物。屏式过热器管超温服役
导致材料组织老化
综合力学性能下降
在高温高压蒸汽作用下发生失效
造成泄漏。
Abstract
The burst cause of a platen superheater tube of T91 steel in certain supercritical units was ana-lyzed by macroscopical morphology
chemical composition
hardness test
OM and SEM observation using the speci-mens exploded platen superheater tube.Results show a low hardness of the failed tube which is related to the micro-structure transformation.The metallographic structure of T91 steel is tempered martensite
while the metallographic struc-ture of the exploded tube doesn't show any martensite at all.The martensite lath is evolved into ferrite and coarsen carbides precipitated at grain boundry.The overheat opera-tion of superheater tube causes the microstructure degrada-tion and the decrease of mechanical properties