GUO Shuang, WANG Yu, WANG Yan-dong. Process Analysis of a 600MW Subcritical Air-cooled Unit Speed Up to 3000r/min[J]. 2017, 38(1): 48-50.
DOI:
GUO Shuang, WANG Yu, WANG Yan-dong. Process Analysis of a 600MW Subcritical Air-cooled Unit Speed Up to 3000r/min[J]. 2017, 38(1): 48-50. DOI: 10.3969/J.ISSN.2095-3429.2017.01.011.
Process Analysis of a 600MW Subcritical Air-cooled Unit Speed Up to 3000r/min
摘要
针对某电厂一台600MW亚临界汽轮发电机组首次启动成功
但第2、3次由于振动大而启动失败的问题
通过对机组启动的运行参数及振动数据进行分析
认为振动大的主要原因是在热态启动过程中
转子发生弯曲。通过盘车消除转子弯曲以及制定针对性的启动措施
使机组再次成功启动
对其他机组启动方式具有借鉴意义。
Abstract
For a 600 MW subcritical Turbo-generator Unit
the first start-up succeed
but the second and the third start-up failed due to the vibration was too large. By analyzing the operating parameters and the vibration data
the result that the rotor was bending was proposed. When the bending restored to normal through barring and then some measures were taken
the fourth start-up succeed. There is reference significance for other units' start-up
Calculation of Heat Transfer Performance of Steam Turbine Shaft Sealing Heater
Experimental Study on Regulation Characteristics of Intermediate Pressure Cylinder Regulating Valves of Heat Supply Steam Turbine Under Peak Regulating Mechanism
Research on Aerodynamic and Strength Performance of Last Stage in High-Pressure Cylinder of Steam Turbine Under Variable Working Conditions
Overview on the Current Situation of Steam Turbine Low-Pressure Cylinder Zero-Output Technology Under Background of Power Grid Peak Regulation
Flutter Prediction Method for Long Blade of Steam Turbine
Related Author
FU Jinglun
BAI Linchao
HE Yaonian
LUO Jianchao
CUI Yongjun
PENG Shuxuan
LIANG Yanfang
ZHANG Yuanshu
Related Institution
University of Chinese Academy of Sciences, Haidian District
Institute of Engineering Thermophysics, Chinese Academy of Sciences, Haidian District
School of Energy and Mechanical Engineering, Nanjing Normal University
Huaneng Beijing Thermal Power Co., Ltd., Chaoyang District