Dynamic Coupling and Cooperative Control for Multi-Paralleled Doubly Fed Induction Generator Wind Farms During Symmetrical Low Voltage Ride-Through in a Weak Grid
Contents|更新时间:2026-09-30
|
Dynamic Coupling and Cooperative Control for Multi-Paralleled Doubly Fed Induction Generator Wind Farms During Symmetrical Low Voltage Ride-Through in a Weak Grid
Protection and Control of Modern Power SystemsVol. 9, Issue 3, Pages: 112-125(2024)
作者机构:
State Key Laboratory of Power Transmission Equipment Technology, School of Electrical Engineering, Chongqing University,Chongqing,China
Lei Guan, Jun Yao. Dynamic Coupling and Cooperative Control for Multi-Paralleled Doubly Fed Induction Generator Wind Farms During Symmetrical Low Voltage Ride-Through in a Weak Grid[J]. Protection and Control of Modern Power Systems, 2024, 9(3): 112-125.
DOI:
Lei Guan, Jun Yao. Dynamic Coupling and Cooperative Control for Multi-Paralleled Doubly Fed Induction Generator Wind Farms During Symmetrical Low Voltage Ride-Through in a Weak Grid[J]. Protection and Control of Modern Power Systems, 2024, 9(3): 112-125.DOI: 10.23919/PCMP.2023.000539.
Dynamic Coupling and Cooperative Control for Multi-Paralleled Doubly Fed Induction Generator Wind Farms During Symmetrical Low Voltage Ride-Through in a Weak Grid
there are complex dynamic interactions between different pieces of equipment. Particularly in situations of weak-grid faults
the dynamic coupling between equipment becomes more pronounced. This may cause the system to experience small-signal instability during the fault steady-state. In this paper
multi-paralleled doubly fed induction generator (DFIG)-based wind farms (WFs) are taken as an example to study the dynamic coupling within a multi-fed system during fault steady-state of symmetrical low voltage ride-through (LVRT) in a weak grid. The analysis reveals that the dynamic coupling between WFs will introduce a damping shift to each WF. This inevitably affects the system's dynamic stability and brings the risk of small-signal instability during fault steady-state in LVRT scenarios. Increasing the distance to fault location and fault severity will exacerbate the dynamic coupling between WFs. Because of the dynamic coupling
adjusting the control state of one WF will affect the stability of the remaining WFs in the system. Hence
a cooperative control strategy for multi-paralleled DFIG WFs is proposed to improve dynamic stability during LVRT. The analysis and the effectiveness of the proposed control strategy are verified by modal analysis and simulation.
Transient Stability Analysis and Coordinated Control Strategy of DC-Link Voltage for PLL-Based Grid-Connected DFIG System During Asymmetrical Grid Faults
Multiple Coupling Characteristics Analysis of Multi-Paralleled Wind Farms During Asymmetrical Grid Faults
Analysis of low voltage ride-through capability and optimal control strategy of doubly-fed wind farms under symmetrical fault
Robust backstepping global integral terminal sliding mode controller to enhance dynamic stability of hybrid AC/DC microgrids
Short-Term Prediction of Wind Farm Cluster Power Based on Bidirectional Interactive Fusion of Homogeneous and Heterogeneous Information
Related Author
Yi Luo
Dong Yang
Hai Xie
Linsheng Zhao
Rongyu Jin
Dong Yang
Jun Yao
Qinmin Zhong
Related Institution
State Key Laboratory of Power Transmission Equipment Technology, The School of Electrical Engineering, Chongqing University
Key Laboratory of Smart Grid of Ministry of Education, Tianjin University
National Industry-Education Platform of Energy Storage, Tianjin University
Department of Electronic and Electrical Engineering, University of Strathclyde, Glasaow
Department of Electrical Power Engineering, Shanghai University of Electric Power