【目的】固体氧化物电解池系统中蒸汽进汽系统的稳定性对提升电解堆的电解效率、延长电解堆寿命至关重要,但蒸汽压力与流量的非线性耦合特性,对控制策略提出了很高要求。【方法】搭建了匹配50 k W级固体氧化物电解池(SOEC)系统的蒸汽进汽系统实验台,研究蒸汽流量误差和压力波动控制。基于采集的实验台运行数据,训练了双延迟深度确定性策略梯度智能体,提出一种基于深度强化学习算法的多目标智能控制(intelligent control
IC)策略,实现了系统输出流量误差不超过3%、压力波动不超过1 kPa的控制目标。【结果】实验表明:IC策略下输出蒸汽流量最大误差为1.4%,压力最大波动量为±0.67 kPa;PID控制方法下系统的稳态输出流量最大误差为3.8%,压力最大波动量为±1.25 k Pa。相较于PID
[Objective] The stability of the steam inlet system in solid oxide electrolysis cell(SOEC) systems is crucial for enhancing the electrolysis efficiency of the electrolytic stack and prolonging its service life. However
the nonlinear coupling between steam pressure and flow rate imposes high demands on the control strategy. [Methods] An experimental platform for the steam inlet system tailored for the 50 k W-class SOEC system was established to investigate the control of steam flow rate error and pressure fluctuation. Based on the collected operation data of the experimental platform
a double-delay deep deterministic policy gradient agent was trained. A multi-objective intelligent control(IC) strategy based on deep reinforcement learning was proposed
aiming to achieve the control goals of the system output flow error not exceeding 3% and pressure fluctuation not exceeding 1 kPa. [Results] The experimental results show that the maximum error of the output steam flow rate under the IC method is 1.4%
and the maximum pressure fluctuation is ±0.67 kPa. While under the PID control method
the maximum error of the steady-state output flow rate of the system is 3.8%
and the maximum fluctuation of the pressure is ±1.25 kPa. Compared with PID control
the IC method reduces the maximum flow rate error by 63.2% and the pressure fluctuation by 46.4%. [Conclusion] The proposed IC method demonstrates significantly superior control performance compared to the PID method.