HUANG Congzhi, JIANG Xixi, TAN Xiangshuai. Error-based active disturbance rejection control and optimization of coordinated control system for ultra-supercritical unit[J]. Thermal Power Generation, 2025, 54(4): 104-116.
DOI:
HUANG Congzhi, JIANG Xixi, TAN Xiangshuai. Error-based active disturbance rejection control and optimization of coordinated control system for ultra-supercritical unit[J]. Thermal Power Generation, 2025, 54(4): 104-116. DOI: 10.19666/j.rlfd.202406175.
Error-based active disturbance rejection control and optimization of coordinated control system for ultra-supercritical unit
ultra supercritical units have become a powerful support for deep frequency regulation
peak shaving
and suppression of power grid fluctuations. The optimization and transformation of control strategies for ultra supercritical units are of great significance for the safe and stable operation of the power grid. Aiming at the optimization problem of coordinated control system for ultra supercritical units
an intelligent control strategy based on error self-disturbance rejection control strategy and reinforcement learning algorithm is proposed. Firstly
in framework of the error-based self-disturbance rejection control strategy
the controlled object model of the machine furnace coupling process is simplified according to operating characteristics of the unit's turbine-boiler coupled process
and an extended state observer is designed to estimate and compensate for the unmodeled dynamic characteristics and external disturbances of the unit in real time. Secondly
a reward function is constructed and the flexible actor-critic algorithm is used to achieve self-adaptive adjustment of controller parameters. Finally
the effectiveness of the proposed control strategy is verified through simulation based on actual historical operating data of a certain ultra supercritical 1 000 MW secondary reheating unit.
STUDY ON LOAD UNDER ECONOMIC OPERATION OF ULTRA-SUPERCRITICAL UNITS
NON-DESTUCTIVE INSPECTION OF AUTOMATIC WELDING DEFECTS FOR BOILER PIPES WITH SMALL DIAMETER AND LARGE WALL-THICKNESS IN ULTRA-SUPERCRITICAL UNITS
CAUSE ANALYSIS OF REAR PLATEN SUPERHEATER LEAKAGE FOR BOILER OF ULTRA-SUPERCRITICAL UNIT AND REMEDIAL MEASURES THEREOF
STRENGTH ANALYSIS OF HOT EXTRUDED TEE-TYPE UNEQUAL-DIAMETER THREE-WAY JOINT FOR MAIN STEAM PIPELINE OF ULTRA-SUPERCRITICAL UNIT
MEASUREMENT AND CALCULATION METHOD FOR THERMAL PERFORMANCE TEST OF ULTRA-SUPERCRITICAL UNIT WITH STEAM TURBINE EQUIPPED WITH DOUBLE-ROW HIGH-PRESSURE HEATERS
Related Author
LEI Zhao-tuanXi’an Thermal Power Research Institute Co Ltd