GUO Zigang, LIU Fan, WU Shuaishuai, et al. Numerical simulation of combustion adjustment of a W-flame boiler at low loads[J]. Thermal power generation, 2025, 54(2): 118-125.
DOI:
GUO Zigang, LIU Fan, WU Shuaishuai, et al. Numerical simulation of combustion adjustment of a W-flame boiler at low loads[J]. Thermal power generation, 2025, 54(2): 118-125. DOI: 10.19666/j.rlfd.202406156.
Numerical simulation of combustion adjustment of a W-flame boiler at low loads
which requires combustion adjustments and other measures. To solve these problems
numerical simulations are conducted to investigate the combustion adjustment of a W-flame boiler under low load conditions. In order to deal with the low steam temperature at low loads
the influence of the position of the recycled flue gas injection and the presence of wall-attached air on the velocity field and temperature field inside the furnace were analyzed. The research results show that introducing recycled flue gas into the furnace by extracting 16% of the total flue gas flow at the air preheater inlet increases the amount of flue gas and improves the convective heat transfer on the heating surfaces. Combined with adjusting the opening of the reheater flue gas baffle
this approach can solve the problem of low reheated steam temperature at low loads. Injecting recycled flue gas from the SOFA air nozzle into the furnace has a minimal impact on the temperature in the primary combustion zone
which benefits the stability of coal combustion at low loads. Introducing 40% of the recycled flue gas as wall-attached air from the side walls of the lower furnace can lower the temperature of the side wall flue gas and transform it into an oxidizing atmosphere
reducing the possibility of side wall coking and high-temperature corrosion.