Simscape-based modeling and fault analysis of gas control valve for gas turbine
domestic research on gas control valves or other equipment in gas turbines is still lacking
while most of these researches' models remain in a single hydraulic valve or a hydraulic cylinder. So this paper uses Simulink/Simscape software to model the entire gas turbine's gas control valve including the PI controller to the gas pipeline
and conduct simulation analysis for faults such as fixed orifice blockage
wear of the spool valve core and hydraulic oil contamination to discuss their forms and causes. The result shows that
the blockage of the one-sided fixed orifice of the nozzle damper valve
the wear of the slide valve core and the impurities in the hydraulic oil will all cause the valve to respond slowly
or even become clogged and stuck to varying degrees.Finally
for the monitoring of valve data in current power plants some suggestions are thrown out: according to the actual operating conditions
monitoring of the parameters such as the servo valve spool displacement signal and hydraulic cylinder piston displacement can be introduced by using electronic feedback servo valve