Investigation on operating characteristics of a 660 MW high moisture lignite-fired boiler under ultra-low load operating conditions
To unveil the ultra-low load operating characteristics and performance optimization method of large-scale units burning high moisture lignite
the influences of burners operating scheme under 33%BMCR condition on the coal combustion
heat transfer and NO_x transformation characteristics of a 660 MW unit utility boiler were investigated
based on an established and validated simulation model of coal-fired boiler. The results show that
well-organized flow and combustion field can still be formed inside the furnace under ultra-low load condition
but the overall boiler performance deteriorates evidently
such as obvious decreases in combustion temperature and heat transfer intensity
and increase in NO_x emission at outlet of the furnace. When 4 layers of burners are in-service
continuous lower-middle groups or middle-upper groups of burners should be put into operation
to prevent the significant deteriorations of combustion and heat transfer processes and the significant increase in NO_x emissions. The number of in-service burners layers significantly affects the overall boiler performance. When there are only two layers of burners in-service
the intense coal combustion area is too concentrated
which is not conducive to maintaining a high combustion temperature and heat transfer intensity
and NO_x emissions at the furnace outlet increase at the same time. These findings reveal the influences of burner operating scheme under ultra-low load condition on the overall performance of a 660 MW lignite boiler
which can provide guidance for deep peak shaving operation adjustment and optimization of coal-fired units in the context of large-scale renewable energy power grid connection in the future.