Scheme design and performance analysis for a 670 MW coal-fired unit coupled with molten salt energy storage system
To address the challenges posed by the reverse peak shaving characteristics of new energy generation units to the smooth operation of the power grid
coal-fired units urgently need to improve their flexible operation and deep peak shaving capabilities. This article proposes three schemes of molten salt heat storage and heat release for a 670 MW reheating unit
including using a steam ejector to allocate the steam inlet flow rate of the reheater. By using Ebsilon to establish the thermal model
this article analyzes the performance of the coupled system. The results show that all schemes can effectively expand the peak shaving range of the unit. Under energy-storage conditions
the thermal economy of steam-extraction is better than using electrical heating at the same peak shaving depth. The heat-storage scheme of integrating steam ejector to allocate extraction steam to compensate for reheat inlet flow can effectively solve the problem of reheater over temperature caused by a large amount of extracted main steam. Under heat-release conditions
using molten salt to heat high pressure feed water can acquire better thermal and economic benefits. In the combination scheme of heat storage and release
C1-S2exhibits the best economic performance
with an upward peak shaving depth of 76.89 MW
and a cyclic thermal efficiency and thermal efficiency of 42.48% and 41.31%