BAI Yan, LU Hongyuan, ZHANG Junhui, et al. Design and research of emergency shutdown equipment for negative pressure inlet condensing turbine[J]. Thermal power generation, 2023, 52(7): 87-91.
DOI:
BAI Yan, LU Hongyuan, ZHANG Junhui, et al. Design and research of emergency shutdown equipment for negative pressure inlet condensing turbine[J]. Thermal power generation, 2023, 52(7): 87-91. DOI: 10.19666/j.rlfd.202306083.
Design and research of emergency shutdown equipment for negative pressure inlet condensing turbine
Conventional industrial steam turbines are usually equipped with quick-closing inlet valves to realize emergency shutdown of the turbine. In this paper
a negative pressure inlet condensing steam turbine was studied has low inlet parameters
large inlet steam volume flow and small pressure difference between inlet and exhaust steam ends. In order to reduce the intake pressure loss
the quick-closing inlet valves are not employed
but a redundant large-diameter rapid vacuum breaker valve is used at the exhaust end of the turbine. When the turbine needs emergency shutdown
open the quick vacuum breaker valve
so that the atmosphere quickly enters the exhaust end of the turbine
the pressure of the exhaust end of the turbine rapidly rises
In this paper
the steam turbine whose inlet and exhaust steam pressure difference is 40 kPa is studied
and the pressure difference between the inlet end and the exhaust end of the turbine could reach 0 within 4 seconds
so that the turbine is closed
and the purpose of emergency shutdown of the turbine is achieved.