Simulation on dynamic characteristics of a supercritical 660 MW once-through boiler
boilers need to have good controllability and the ability to adapt to rapid load changes. The flexibility of the boiler is closely related to the performance of the control system
which is designed according to the dynamic characteristics of boilers. To study the dynamic characteristics of boilers
a dynamic model of a supercritical 660 MW coal-fired boiler is built in the Dymola platform. The results show that the response time of steam temperature is longer than that of steam flow. When the feedwater temperature
feedwater flow
and fuel quantity are stepped increase by 5%
the main steam temperature changes by 10.2 ℃
–28.5 ℃
and 35.7 ℃
respectively. In the process of adjusting the water-fuel ratio of the boiler
different times of change in feedwater and fuel flow can have different effects on the main steam temperature. The maximum deviation of the main steam temperature during the transient process reduces by 27.4 ℃ when the feedwater flow is delayed by approximately 100 s compared with the fuel flow. When the load change amplitude is the same
the larger the load change rate
the more severe the fluctuation of the main steam parameters
MATHEMATIC MODEL AND DYNAMIC CHARACTERISTICS OF ONCE-THROUGH BOILER FOR A 300 MW UNIT
Simulink based dynamic characteristics simulation for water wall on an ultra supercritical boiler
Fuzzy control system for intermediate point enthalpy based on feedforward of feed-water temperature
Simulation modelling of power system for supercritical units considering dynamic heat exchange of once-through boiler
PRELIMINARY ANALYSIS OF REQUIREMENTS TO WATER-WALL SYSTEM PERFORMANCE FOR SERVICE OPERATION OF SUPERCRITICAL PRESSURE ONCETHROUGH BOILER OF 600MW UNITS
Related Author
CAI Dan
LENG Wei(Southeast China University
CHANG Jingwei
TIAN Xiaoxuan
HUANG Jintao
YANG Zihao
ZHANG Yanping
GAO Wei
Related Institution
Southeast University
Xi'an Thermal Power Research Institute Co., Ltd
School of Energy and Power Engineering, Xi'an Jiaotong University
School of Energy and Power Engineering, Huazhong University of Science and Technology