WANG Yan, WANG Yang, LYU Kai, et al. Thermal performance analysis of the coupled system of cogeneration unit and liquid carbon dioxide energy storage system[J]. Thermal power generation, 2023, 52(8): 40-50.
DOI:
WANG Yan, WANG Yang, LYU Kai, et al. Thermal performance analysis of the coupled system of cogeneration unit and liquid carbon dioxide energy storage system[J]. Thermal power generation, 2023, 52(8): 40-50. DOI: 10.19666/j.rlfd.202304059.
Thermal performance analysis of the coupled system of cogeneration unit and liquid carbon dioxide energy storage system
Coupled with the energy storage system can improve the peak shaving capacity of the thermal power unit. To improve the thermoelectric decoupling ability of the combined heat and power unit
a coupled thermal power plant combined heat and power unit with liquid carbon dioxide energy storage system is proposed. The system utilizes the condensate to recover the compression heat of the carbon dioxide during the charge process
and supplies heat to the users together with the heating extraction steam. Besides
the heating extraction steam is employed to preheat the carbon dioxide of the expander inlet during the discharge process. Based on the established thermodynamic models
the thermal performance analysis of the coupled system was carried out with the thermal efficiency
exergy efficiency
and electricity storage efficiency as assessment criteria. The sensitivity analysis results indicate that increasing both the expander inlet temperature and the discharge pressure can obtain a higher system exergy efficiency and electricity storage efficiency; increasing the charge pressure results in a higher system thermal efficiency
while the exergy efficiency first increases and then decreases. The parameter optimization of the corresponding CO_2 energy storage system was carried out under the design parameters. Results show that when the charge pressure is 10.5 MPa and the discharge pressure is 18.0 MPa
the coupled system achieves the optimal efficiency of 64.92%.