WEI De, XI Xinming, LI Jian, et al. Study on off design characteristics of high back pressure unit coupled with ejector[J]. Thermal power generation, 2023, 52(5): 107-114.
DOI:
WEI De, XI Xinming, LI Jian, et al. Study on off design characteristics of high back pressure unit coupled with ejector[J]. Thermal power generation, 2023, 52(5): 107-114. DOI: 10.19666/j.rlfd.202209218.
Study on off design characteristics of high back pressure unit coupled with ejector
Under the background of auxiliary heat supply of ejector
in order to study the characteristics of ejector under variable working conditions
the calculation methods of ejector at home and abroad are investigated
the ejector calculation model is established and coupled with the high back pressure unit. Moreover
the effects of working steam
ejected steam
ejector back pressure
and ejector opening on the performance of the ejector under variable working conditions are obtained. The results show that
when the working fluid pressure of the ejector changes from 0.25 MPa to 0.45 MPa
the mass flow of the working fluid first increases and then decreases
and the ejector has the best performance at the design working steam pressure. The critical back pressure increases with the steam injection pressure. The pressure of the mixed fluid after injection will not only affect the work of the ejector but also the work of the condenser. Compared with the back pumping unit
the minimum cooling flow of the low pressure cylinder of the high back pressure coupling injector unit can be reduced by 140 t/h and the power supply range can be increased by 43 MW.