ZHOU Yu, LI Jinghao, ZHANG Wanfu. Vibration reduction method for condensate pump motor based on dynamic vibration absorber[J]. Thermal power generation, 2023, 52(5): 48-54.
DOI:
ZHOU Yu, LI Jinghao, ZHANG Wanfu. Vibration reduction method for condensate pump motor based on dynamic vibration absorber[J]. Thermal power generation, 2023, 52(5): 48-54. DOI: 10.19666/j.rlfd.202208161.
Vibration reduction method for condensate pump motor based on dynamic vibration absorber
analysis on abnormal vibration of vertical condensate pump motor and vibration reduction measures are carried out. According to the vibration characteristics of the condensate pump motor
the design method of power vibration absorption is studied theoretically
and the power vibration absorber is developed and designed and applied to the actual unit. The results show that
the dynamic balancing method has certain limitations in alleviating the vibration exceedance of the condensate pump motor during varying frequency operation
and cannot reduce the vibration amplitude of the condensate pump motor in both directions at the same time. The mass participating in the vibration of the condensate pump system shows a growing change with the increasing additional mass
and the first-order vibration mass at the top of the condensate pump motor is about 6 000 kg(X direction) and 7 000 kg(Y direction). With mass ratio of 2%
5% and 10%
the maximum vibration amplitude in X direction is reduced by 80%
83% and 86%
and the maximum vibration amplitude in Y direction is reduced by 68%
77% and 83%. The dynamic vibration absorber device effectively reduces the vibration in both directions
and the actual reduction of vibration in X and Y directions is about 53% and 66% during the whole frequency operation period. The vibration control method based on the dynamic vibration absorber of the condensate pump motor has an excellent vibration reduction effect.
REALIZATION OF ZERO SPECIFIC CONSUMPTION FOR CONDENSATE PUMPS,CIRCULATING-WATER PUMPS,AND MOTOR-DRIVEN FEED-WATER PUMPS DURING START-UP PROCESS OF 300MW UNITS
FREQUENCY CONVERSION RETROFIT AND ENERGY-SAVING OF CONDENSATE PUMP IN HUAYU POWER PLANT
PROBLEMS OCCURRED FROM ADDITIONALLY INSTALLING HIGH-VOLTAGE FREQUENCY CONVERTER ONTO CONDENSATE PUMPS AND SOLVING MEASURES THEREOF
ENERGY-SAVING RETROFIT OF THE CONDASATE SYSTEM FOR HOME-MADE 300MW UNITS AND ECONOMIC EFFICIENY ANALYSIS THEREOF
FREQUENCY CONVERSION RETROFIT OF CONDENSATE PUMP FOR 330 MW UNIT AND SYSTEM OPEATION OPTIMIZATION THEREOF
Related Author
ZHOU DaGuang'an Power Generation Co Ltd
XIONG Kang-jun Datang Huayu Power Generation Co Ltd
HUANG Li-li21.Huaibei Guo'an Electric Power Co Ltd