Membrane fouling analysis for zero liquid discharge treatment system in a power plant
a power plant treated circulating wastewater by the combination process of two stage softening and clarification
media filtration
ultrafiltration
nanofiltration(NF) and reverse osmosis(RO)
and treated terminal wastewater by the combination process of chemical softening
tubular microfiltration(MF)
NF
seawater desalination reverse osmosis
electrodialysis(ED) and evaporative crystallization. After the above measures were taken for 1 year
insufficient NF output was found in the circulating wastewater treatment system
and serious MF membrane organic fouling and ED silicon scaling was observed in the terminal wastewater treatment system. Thus
the causes of the membrane fouling was analyzed and the desulfurization process water was optimized to reduce the chemical oxygen demand(COD) of desulfurization wastewater from the source. Moreover
the MF operation mode was optimized
so as to slow down the MF organic pollution phenomenon. In addition
the RO concentrated water of circulating water treatment mode was adjusted
and the total silicon mass concentration was reduced to less than 1 mg/L before being fed into the ED equipment