Optimization of main steam temperature deviation on both sides of supercritical 600 MW opposed firing boiler based on hydrodynamic model of flow network method
|更新时间:2025-09-28
|
Optimization of main steam temperature deviation on both sides of supercritical 600 MW opposed firing boiler based on hydrodynamic model of flow network method
Thermal Power GenerationVol. 52, Issue 1, Pages: 74-82(2023)
LI Songshan, TANG Wen, NING Xinyu, et al. Optimization of main steam temperature deviation on both sides of supercritical 600 MW opposed firing boiler based on hydrodynamic model of flow network method[J]. Thermal power generation, 2023, 52(1): 74-82.
DOI:
LI Songshan, TANG Wen, NING Xinyu, et al. Optimization of main steam temperature deviation on both sides of supercritical 600 MW opposed firing boiler based on hydrodynamic model of flow network method[J]. Thermal power generation, 2023, 52(1): 74-82. DOI: 10.19666/j.rlfd.202205088.
Optimization of main steam temperature deviation on both sides of supercritical 600 MW opposed firing boiler based on hydrodynamic model of flow network method
By taking a supercritical 600 MW opposed firing boiler as the research object
the temperature deviation law of main steam on both sides is analyzed and verified through hydrodynamic modeling
and a technical scheme is put forward to optimize the temperature deviation of main steam from the perspective of water side. After adopting this steam temperature optimization scheme
the main steam temperature deviations on both sides of the boiler reduced by 44.6%
95.8% and 28.0% respectively under 50%
75% and 100% BRL conditions. This scheme can realize safe and economical operation of the unit
and has good guidance and reference value for the same type of boiler.