ZHOU Ke, HE Minqiang, NIU Tiantian, et al. Research on hydrodynamic characteristics at deep peak load regulation of 660 MW supercritical lignite boiler[J]. Thermal power generation, 2022, 51(9): 88-95.
DOI:
ZHOU Ke, HE Minqiang, NIU Tiantian, et al. Research on hydrodynamic characteristics at deep peak load regulation of 660 MW supercritical lignite boiler[J]. Thermal power generation, 2022, 51(9): 88-95. DOI: 10.19666/j.rlfd.202203040.
Research on hydrodynamic characteristics at deep peak load regulation of 660 MW supercritical lignite boiler
Sustainable development of energy and high quality development of national economy have made deep peak shaving an indispensable part of thermal power generation technology. The characteristics of large furnace and low mass flow rate of supercritical lignite boiler are disadvantageous to ensure sufficient cooling of water wall and stable flow at low load. In order to ensure safe and stable operation of the furnace during deep peak load and improve the economy of unit peak shaving operation of a supercritical 660 MW lignite boiler
the method of equating the water wall flow network system to three types of components(flow loop
pressure node and connecting pipe) is adopted. According to the conservation law followed by nodes and loops
the accuracy of the model is verified by comparing the calculated results with the measured data of the actual furnace at 648 MW
and the hydrodynamic safety parameters of the water wall at 198 MW(30% BMCR) in the furnace depth peak shaving are analyzed. The calculation results show that
at 198 MW
the maximum mass flow deviation of the furnace under the water wall is 3.03%
that of the upper furnace is 13.66%
the maximum deviation of steam temperature of the upper and lower furnaces is 9.6 ℃ and 9.7 ℃
and the highest outer wall temperature is 473.8 ℃. Both the temperature deviation and the highest outer wall temperature are within a reasonable range
so the safety of hydrodynamic operation under 30% BMCR deep peak load regulation is realized
and the flow stability characteristics are good. It is of great significance to lignite boilers for further breaking through the limit of the lowest start-up load during deep peak regulation.
Actual furnace test research on hydrodynamics of a supercritical boiler at 20% deep peak load
Experimental study on banked fire for peak regulation of supercritical circulating fluidized bed units
Experimental study on start-stop peak regulation of a 350 MW supercritical circulating fluidized bed coal-fired power unit
PRELIMINARY ANALYSIS OF REQUIREMENTS TO WATER-WALL SYSTEM PERFORMANCE FOR SERVICE OPERATION OF SUPERCRITICAL PRESSURE ONCETHROUGH BOILER OF 600MW UNITS
AN APPROACH TO FEASIBILITY AND ECONOMIC BEHAVIOR OF ADOPTING DIRECT DRY TYPE COOLING SYSTEM FOR SUPERCRITICAL UNITS
Related Author
WU Pengjü
ZHU Chao
WAN Li
YANG Dong
XING Shengli
XU Yong
TONG Boheng
LI Yu
Related Institution
State Grid Shaanxi Electric Power Company Electric Power Science Research Institute
Huaneng Shaanxi Qinling Power Generation Co., Ltd
North China Electric Power Research Institute Co., Ltd
Jijian Investment Shouyang Thermal Power Co., Ltd
Department of Energy and Power Engineering, Tsinghua University