ZHANG Jinzhe, CHEN Hongyu, ZHANG Yu, et al. Effect of mass concentration of sulfate ions in high temperature water on stress corrosion cracking behavior of Z3CN20.09 stainless steel[J]. Thermal power generation, 2022, 51(9): 162-169.
DOI:
ZHANG Jinzhe, CHEN Hongyu, ZHANG Yu, et al. Effect of mass concentration of sulfate ions in high temperature water on stress corrosion cracking behavior of Z3CN20.09 stainless steel[J]. Thermal power generation, 2022, 51(9): 162-169. DOI: 10.19666/j.rlfd.202201034.
Effect of mass concentration of sulfate ions in high temperature water on stress corrosion cracking behavior of Z3CN20.09 stainless steel
the effect of sulfate mass concentration in primary circuit water of the pressurized water reactor(PWR) on stress corrosion cracking(SCC) sensitivity of Z3CN20.09 casted austenitic stainless steel(CASS) was investigated. The results show that
necking occurred near the fracture after the SSRT of Z3CN20.09 CASS in 6 water environments. In normal PWR water containing no SO_4~(2–)
the elongation to fracture of Z3CN20.09 CASS was the largest
and the rupture surfaces were dimple-like facets
indicating that the Z3CN20.09 CASS has excellent SCC resistance under this condition. SSRT samples showed significant SCC sensitivity in high-temperature water containing 100~1 500 μg/L SO_4~(2–)
and the fracture showed transgranular plus dimple mixed face. The corrosion sensitivity of different phases and phase boundaries to SO_4~(2–) and the deterioration effect of SO_4~(2–) on passive film on the alloy surface are thought to be the key factors for enhancing localized corrosion and SCC.
CAUSE ANALYSIS OF REINFORCING WIRES FAILURE FOR INCOMING GAS SAFETY ISOLATING STRAINER OF THE GAS TURBINE
OPTIMIZATION OF TEST CONDITIONS FOR EVALUATING SCALE-INHIBITOR'S PERFORMANCE BY USING CONSTANT POTENTIAL CATHODIC POLARIZATION METHOD
Experimental study on growth rate of oxide scale on superheater and reheater tubes in ultra-supercritical units
Experimental study on critical conditions for pitting corrosion of 316L and 317L heat exchange plate used in 130 ℃ circulating water in heating network
Effect of chloride ion mass concentration on stress corrosion cracking performance of Inconel 740H alloy
Related Author
GAO Yan et al
GAN Meng-bi
CHEN Peng
ZHOU Guoding1 1.Research Center of Energy-saving in Heat Exchange System
LI Mingli2
LIANG Lei1
LIN Jianzhen1
LIU Shaoqiang
Related Institution
Moon Bay Gas Turbine Power Plant
South China University of Technology
Energy saving Engineering Technology Research Center for Heat Exchange Systems at Shanghai Electric Power University