CHEN Shengguang, WANG Junmin, DENG Linghui, et al. Cause analysis on abnormal displacement of high temperature reheat steam pipeline and the prevention research and application[J]. Thermal power generation, 2022, 51(5): 169-174.
DOI:
CHEN Shengguang, WANG Junmin, DENG Linghui, et al. Cause analysis on abnormal displacement of high temperature reheat steam pipeline and the prevention research and application[J]. Thermal power generation, 2022, 51(5): 169-174. DOI: 10.19666/j.rlfd.202112261.
Cause analysis on abnormal displacement of high temperature reheat steam pipeline and the prevention research and application
In order to find out the causes of abnormal large displacement of high temperature reheat steam pipe and serious underload
overload and even crushing of several groups of supports and hangers after an ultra-supercritical 1 000 MW unit was put into operation
the calculation model and evaluation method of pipeline mechanics covering the measured performance indexes of constant support hanger were established
and the causes of abnormal displacement of high temperature reheat steam pipeline were systematically and quantitatively studied. The analysis shows that
the main causes of the abnormal displacement are the multi-bend and multi-undulating arrangement of the high temperature reheat steam pipeline
less rigid constraints in the vertical direction
more continuous arrangement of the constant support hangers
and the performance of the constant support hangers exceeds the standard. After the prevention and control measures of sectional restraint con20trol and load compensation were implemented
the measured value of the thermal displacement of the high-temperature reheat steam pipe is close to the calculated value
the abnormal large displacement has been eliminated
and the mechanical safety of the pipeline and the supports and hangers has been greatly improved.