Study on influence of operating parameters on gas-solid flow characteristics of four-cycle loop of a 660 MW high-efficiency ultra-supercritical CFB boiler
|更新时间:2025-09-28
|
Study on influence of operating parameters on gas-solid flow characteristics of four-cycle loop of a 660 MW high-efficiency ultra-supercritical CFB boiler
Thermal Power GenerationVol. 51, Issue 3, Pages: 96-101(2022)
HAN Ping, ZHANG Dongwang, XIN Shengwei, et al. Study on influence of operating parameters on gas-solid flow characteristics of four-cycle loop of a 660 MW high-efficiency ultra-supercritical CFB boiler[J]. Thermal power generation, 2022, 51(3): 96-101.
DOI:
HAN Ping, ZHANG Dongwang, XIN Shengwei, et al. Study on influence of operating parameters on gas-solid flow characteristics of four-cycle loop of a 660 MW high-efficiency ultra-supercritical CFB boiler[J]. Thermal power generation, 2022, 51(3): 96-101. DOI: 10.19666/j.rlfd.202110206.
Study on influence of operating parameters on gas-solid flow characteristics of four-cycle loop of a 660 MW high-efficiency ultra-supercritical CFB boiler
As the capacity of circulating fluidized bed(CFB) boiler increases
the number of separators increases accordingly
and the structure of parallel arrangement of multiple separators will result in uneven gas-solid distribution and bias flow phenomenon
which brings great harm to the boiler. To investigate the effects of different operating parameters on the bias flow phenomenon
an Eulerian two-fluid model was used to carry out numerical simulation on the gas-solid flow characteristics of high efficiency ultra supercritical CFB boiler with four separators arranged in M type. The effects of air distribution uniformity
average particle size and volume ratio of primary air to secondary air on the gas-solid distribution uniformity among multiple separators were discussed in detail.Compared with bed stock and the primary and secondary air ratio
the uniformity of air distribution had the greatest influence on the gas-solid flow rate distribution between the four circulation loops. Therefore
ensuring the distribution uniformity of air distribution is the main measure to solve the gas-solid bias flow. Moreover
the nonuniformity of gas-solid distribution in the four separators increases at first and then decreases with the increase of particle size.