ZOU Siyu, ZHENG Puyan, BAI Tianyu, et al. Research on heat storage schemes for peak shaving of condensing unit considering carbon trading[J]. Thermal power generation, 2022, 51(4): 10-17.
DOI:
ZOU Siyu, ZHENG Puyan, BAI Tianyu, et al. Research on heat storage schemes for peak shaving of condensing unit considering carbon trading[J]. Thermal power generation, 2022, 51(4): 10-17. DOI: 10.19666/j.rlfd.202109216.
Research on heat storage schemes for peak shaving of condensing unit considering carbon trading
The extraction staged heat storage is applied to condensing unit peak shaving
and “three-stage” and “two-stage” heat storage and release structures are put forward based on the principle of energy cascade utilization.The changes of peak shaving range
CO_2 emission and income under different schemes are studied. Taking an ultra supercritical 660 MW unit as an example
the above two heat storage and release structures are compared with the existing “single-stage” heat storage and release structure. The 40%THA working condition is taken as the initial working condition to store heat for No.1
No.2 and No.3 regenerative extraction steam
respectively. The results show that
the peak shaving range of the “three-stage” and “two-stage” structure is 31.5%~45.2%
which is greater than that of the “single-stage” storage and discharge structure. In a heat storage and release cycle
the carbon emission of the heat storage peak shaving scheme is almost equal to that of the control scheme without heat storage
but the carbon quota is less than that of the control scheme
resulting in the reduction of carbon trading income.However
after adding the peak shaving income of each heat storage scheme
the total income is higher than that of the control scheme
and the scheme that “storages extraction steam of the first stage of high pressure heater” with “three-stage” structure has the highest total income.