ZHANG Jiangtao, ZHU Xuebing, DONG Juan, et al. Application and evaluation of combined process of circulating cooling water blowdown treatment[J]. Thermal power generation, 2021, 50(11): 158-164.
DOI:
ZHANG Jiangtao, ZHU Xuebing, DONG Juan, et al. Application and evaluation of combined process of circulating cooling water blowdown treatment[J]. Thermal power generation, 2021, 50(11): 158-164. DOI: 10.19666/j.rlfd.202104078.
Application and evaluation of combined process of circulating cooling water blowdown treatment
By taking the circulating cooling water blowdown treatment process of Huaneng Chaohu Power Plant as a typical case
the process of purifying the circulating cooling water blowdown of thermal power plants using a combined physicochemical-biological process to meet the discharge standards was investigated
and the contribution rates of different process units to the removal of various pollutants were evaluated. The results show that
the combined technology of physicochemical and biological
including biological aerated filter
coagulation clarifier
ozonation contact reactor
biological activated carbon filter and quartz sand filter
could achieve efficient and stable treatment of circulating cooling water blowdown in thermal power plant
and after treatment
the water quality could meet the relevant requirements of Class IV in the Environmental Quality Standards for Surface Water(GB 3838—2002). The biological aerated filter and biological activated carbon filter realized the efficient removal of nitrogen and organic matters in the circulating cooling water blowdown of thermal power plants. Coagulation clarifier and biological activated carbon filter played an important role in the removal of turbidity
total phosphorus
dissolved total phosphorus and phosphate in circulating cooling water blowdown
while the quartz sand filter at the end of the process ensured the stable discharge of effluent turbidity. The ozonation contact reactor could not only greatly improve the biodegradability of the circulating cooling water blowdown
but also facilitated the further purification of pollutants in the followed biological treatment unit. The study provides important reference for the treatment of circulating cooling water blowdown in thermal power plants with similar water quality and discharge requirements.